With Xtratherm’s Advanced Detailing and engineered jointing of boards the insulation continuity of your project is assured.
Use the filter option to view the ACD Certificates per block weight:
With Xtratherm’s Advanced Detailing and engineered jointing of boards the insulation continuity of your project is assured.
Use the filter option to view the ACD Certificates per block weight:
Timber Intermediate Floor
ACD Ref. XT-CTPIR-1.05-Inter-floor-Rev-3
Table D1. 1.05
Y. 0.00
f. 0.98
Masonry Separating Wall (Solid)
ACD Ref. XT-CTPIR-1.06.1-Separating-Wall-Plan-Rev-3
Table D1.
Y. 0.03
f. 0.98
Masonry Separating Wall (Cavity)
ACD Ref. XT-CTPIR-1.06.2-Separating-Wall-Plan-Rev-3
Table D1.
Y. 0.03
f. 0.98
Eaves (Ventilated/Unventilated)
ACD Ref. XT-CTPIR-1.09-1.10-Eaves-Rev-3
Table D1.
Y. 0.06
f. 0.94
Flat Roof - Eaves
ACD Ref. XT-CTPIR-1.19-Flat-Roof-Eaves-Rev-3
Table D1.
Y. 0.03
f. 0.97
Ventilated Roof - Attic Floor Level
ACD Ref. XT-CTPIR-1.15-Attic-Floor-Rev-3
Table D1.
Y. 0.20
f. 0.87
Ope - Perforated Steel Lintel
ACD Ref. XT-CTPIR-1.22-Steel-lintel-Rev-3
Table D1.
Y. 0.04
f. 0.95
Flat Roof - Parapet
ACD Ref. XT-CTPIR-1.20-Flat-Roof-Parapet-Rev-3
Table D1.
Y. 0.21
f. 0.91
Ope - Jamb with Closer Block
ACD Ref. XT-CTPIR-1.24-Jamb-closer-block
Table D1.
Y. 0.03
f. 0.96
Ope - Prestressed Concrete Lintel
ACD Ref. XT-CTPIR-1.23.2-Concrete-lintel-Rev-3
Table D1.
Y. 0.00
f. 0.95
Ope - Jamb with Proprietary Cavity Closer
ACD Ref. XT-CTPIR-1.25-Jamb-cavity-closer-Rev-3
Table D1.
Y. 0.01
f. 0.95
Ope - Concrete Forward Sill
ACD Ref. XT-CTPIR-1.26-Sill
Table D1.
Y. 0.03
f. 0.94
Internal Corner
ACD Ref. XT-CTPIR-1.27.2-Inverted-Corner-Rev-3
Table D1.
Y. -0.06
f. 0.98
External Corner
ACD Ref. XT-CTPIR-1.27.1-Ext-Corner-Rev-3
Table D1.
Y. 0.04
f. 0.96
Ground Floor - Insulation Above Slab
ACD Ref. XT-CTPIR-G.05.1-Separating-Solid-Wall
Table D1.
Y. 0.15
f. 0.94
Ground Floor - Insulation Above Slab
ACD Ref. XT-CTPIR-G.05.2-Separating-Narrow-Wall
Table D1.
Y. 0.16
f. 0.92
Ground Floor - Insulation Above Slab
ACD Ref. XT-CTPIR-1.01b-Wall-floor-Rev-3
Table D1.
Y. 0.06
f. 0.91
Ground Floor - Insulation Above Slab
ACD Ref. XT-CTPIR-1.01a-Wall-floor-Rev-3
Table D1.
Y. 0.17
f. 0.83
Ground Floor - Insulation Below Slab
ACD Ref. XT-CTPIR-1.02a-Wall-floor-Rev-3
Table D1.
Y. 0.17
f. 0.85
Ground Floor - Insulation Below Slab
ACD Ref. XT-CTPIR-1.02b-Wall-floor-Rev-3
Table D1.
Y. 0.08
f. 0.91
Concrete Intermediate Floor within a Dwelling
ACD Ref. XT-CTPIR-1.04-Inter-floor-Rev-3
Table D1.
Y. 0.00
f. 0.98
Concrete Intermediate Floor Between Dwellings
ACD Ref. XT-CTPIR-1.04a-Inter-floor-Rev-3
Table D1.
Y. 0.02
f. 0.98
Timber Intermediate Floor between Dwellings
ACD Ref. XT-CTPIR-1.05a-Inter-floor-Rev-3
Table D1.
Y. 0.02
f. 0.98